INVERTERS: WF-5110RS

Product Description

WF-5110RS

WFCO’s WF-5110RS is the new and improved 1000-watt inverter in our product line. The new design reduces parasitic draw, while maximizing battery power and efficiency. Featuring automatically resettable Reverse Polarity protection, the WF-5110RS is protected from permanent damage should a battery be connected backwards. Once the battery connections are corrected, the unit will operate normally. The WF-5110RS also has an exclusive internal transfer system which automatically allows the AC input to bypass the inverter when the inverter is connected to an AC power source. WFCO’s WF-5110RS improved upon the same reliable inverter that customers have come to love, with the added benefit of a longer lasting battery that customers need.

Additionally, the WF-5110RS provides high-efficiency power at full-load conditions with safeguards that include overload protection, over-temperature protection, and short-circuit protection. The cooling fan enhances efficiency as its operation is controlled by the amount of load incurred by the inverter. FCC Class B compliance, which means that the inverter is designed not to cause interference with televisions, radios, or other signals.


Additional Information

Output Waveform

Pure Sine Wave (THD <3%)

Efficiency (full load)

>86%

Continuous Output Power

1000 W

Status Indicator Lights

Greed LED: AC Input Status, Red LED: Inverter Failure, Yellow LED: Battery Back Up Status

Transfer Switch

10 A, Automatic transfer to battery power

Transfer Time

20 milliseconds

Protection Features

AC Output Fuse, GFCI, Over Temperature, Over/Under Input Voltage, Overload, Reverse Polarity (fuse), Short Circuit

Cooling

Load Controlled Cooling Fan

Output Wiring

Hard Wired

Certifications

FCC Class B compliant

Listed

UL 458

Dimensions

14.6″ L x 11″ W x 3.9″ H

Weight

11.72 lb

Watts

1KW

Input Voltage/Hz

120 VAC, 60 Hz

VDC

12

Input Nominal Voltage

12VDC

Input Voltage Range

10.5 – 16.2 Vdc

AC Voltage Regulation

+/- 3% from no load to full load under battery range

Remote Control Panel

Yes

Overload Protection

Current limiting & shutdown

Over Temperature

System shut down

Output Power

Protected by fuse: 12A/125V Circuit Breaker

Input Connection

4AWG or 2AWG wires required with 100A in-line slow blow fuse

Environmental

0-40 degrees C / 20-90% non-condensing

PRODUCT DOCUMENTS